Battery operation and charging
LabSat 3 variants that include internal battery use replaceable Varta Li-Polymer battery packs. These packs
are fully certified (UL, CE, UN38.3 Transport). Each pack gives around 2 hours of record time. When the
LabSat 3 is powered externally, it will charge the internal battery pack if fitted and seamlessly switch over
to battery operation when external power is removed. Alternatively, an external battery charger is
available to order.
To remove the battery from LabSat 3, unscrew the battery plate on the rear of the device and slide the
battery out.
When operating from battery power, the battery charge status will be shown in the top-right section of the
display . If external power is connected and the battery is being charged, a power symbol will be
shown over the battery symbol. The discharge temperature range for the battery is -20°C to +60°C.
Therefore, if the LabSat is operating from battery power, it will power-down if the temperature falls outside
this range.
The charge temperature range of the battery pack is 0°C to +45°C. Outside this temperature range, the
LabSat will switch off charging of the internal battery but will continue to operate from the external power
supply.
Warning - Li-Polymer Battery Pack - Risk of fire or explosion.
Do not incinerate, disassemble, short terminals, expose to temperature above
140°F/60°C.
Do not charge battery unattended, expose of batteries in fire or disassemble the
batteries.